Trunionosisqué es y en qué me afecta?
- Reyes Jiménez, A. 1
- Zamora Navas, P. 2
- Delgado Martínez, A.º 1
-
1
Hospital Universitario de Jaén
info
- 2 Hospital Clínico Universitario de Málaga
ISSN: 1578-9756
Année de publication: 2017
Volumen: 34
Número: 2
Pages: 17-22
Type: Article
D'autres publications dans: Revista de la Sociedad Andaluza de Traumatología y Ortopedia
Résumé
Trunnionosis is defined as wear of the femoral head-neck interface, has recently been acknowledged as a cause of total hip arthroplasty failure. It is responsible of 3% of all total hip arthroplasty revisions. The exact cause is unknown, however postulated etiologies included modular junction wear, corrosion damage, and metal ions. To prevent this, it is recommended to use ceramic heads, use short necks and with low offset if possible, and with heads not too large.